We have gained proficiency in manufacturing, supplying, wholesaling and trading a wide range of Maximum Controller Panel to the valuable clients. Offered products are manufactured in adherence with the industry laid parameters under the supervision of our experienced professionals. The raw material used is obtained by the certified vendors of the market. To meet the diverse requirements of the customers, we customize our range according to specification given by customers.
Features:
We are one of the well-known manufacturers and suppliers of Demand Control Panel. The offered demand control panel is used to sound an alarm, at the attainment of a pre-set load value. Our offered control panel is required, for checking the overload power usages in the premises, at any given point in time. The offered control panel is very useful for the load conscious industries.
Features:
Demand controli is a method of controlling the consumption not to overload the grid. Demand is calculated in different ways, different parameters depends on the region/country. There are two types of demand measurement names sliding window & fixed (block) window, forecast demand control & step wise demand control.
Features:
MDC Controller users often have to pay a maximum demand charge in addition to the usual charge for units consumed. This charge usually based on the highest amount of power used during some period (say maximum demand charge often represents a large proportion of the total bill. Considerable savings by monitoring power use & turning off or reducing non-essential loads during such periods of high The MDC-1000 reduced their maximum demand in an economical manner.
Maximum demand is calculated by two different modes 1) fixed window technique 2) Sliding window t synchronized with RTC This meter is also monitor the line voltage, current, frequency, power factors, reactive power, apparent power, active energy, reactive energy, & apparent energy in a Three phase phase system. It has an in-built real time clock.
In short it serves as a useful tool in conserving and saving energy. It also has some important feature P.T. ratio and C.T. ratio, by which a user can read the actual voltages and currents in places where high voltage is used (to monitor high tension lines). It has a password feature so that nobody can tamper with the energy data is retained in case of power failures. So this unit finds applications in almost all the industries complexes, hospitals, electrical generating & substations, hotels etc.
Features:
Type | 3 Ph/3 El/4 W |
Measurement | True R.M.S |
Input voltage | 240 V/440 VAC, burden 0.5 VA |
Input current | 5 A burden 0.5 VA |
Operating frequency | 45 Hz to 65 Hz |
Operating power factor | 0.1 lag-unity-0.1 lead |
Auxiliary supply | 90 VAC- 265 VAC, 120 VDC to 300 VDC, 5 VA |
Accuracy | Power: ±1% of full scale Energy: ±1% of the reading PF: ±2 Voltage and current: ±0.5 of full scale Frequency: ±0.2% of full scale |
Resolution: | Power: ±0.2% of full scale Voltage and current: ±0.1% of full scale Power factor: ±0.3” Frequency: ±0.01% of centre frequency |
Display | 16 char x 2 rows backlit LCD display |
Response time | Less than 500 ms |
Over voltage | 1.5 times for 10 second |
Over current | 10 times for 3 seconds |
Insulation resistance | Greater than 20 M at 500 V DC |
Dielectric test | 2 kV RMS for 1 min |
Operating temperature | 0º to 55º C |
Storage temperature | -20º C to 70º C |
Humidity | Up to 95% RH |